Diagnosing button faults: double-triggers, no response, phantom presses, and the debounce and wiring checks.

Button Troubleshooting

Buttons are the most mechanically stressed part of the beacon: they get pressed in the cold, with gloves, thousands of times. Their faults are distinctive, and most are wiring, not firmware.

The symptom map

SymptomLikely cause
No response at allWiring, or wrong pin in config
Double-triggersNo pull resistor, or electrical noise
Works but stickyDebris in the switch
Works cold, not warm (or reverse)Cold solder joint expanding
Phantom presses at randomNoise on the line, or water ingress

The wiring check

  1. With the beacon off, measure continuity between the button pins: open when released, closed when pressed.
  2. Verify the firmware’s configured pin matches the wired pin (see GPIO Pin Mapping).
  3. Check the pull resistor: the line must be held high (or low) when the button is released.

Debounce

The firmware debounces in software (see Firmware Buttons), but it cannot fix a missing pull resistor: a floating line reads random presses. If double-triggers persist with the pull in place, add a 100 nF capacitor across the button.

The glove problem

In winter, stiff gloves make presses slow and partial. If a press does not register, the user presses harder, and membrane buttons can stick. The fix is mechanical: buttons with more travel, or the firmware’s press-and-hold alternatives (see Button Actions in Config).

The water problem

Water between the contacts reads as a phantom press. After wet trips, dry the buttons and check the case seal (see Waterproofing).